DIGITAL CLAMP-ON-MULTIMETER WITH VFD FUNCTION

We are a well appreciated exporter, importer and trader of best quality Digital Clamp-On-Multimeter With VFD Function. It is the perfectly engineered digital meter used for the measurement function in various industry specific applications. After years of research, a perfect design is developed for the offered meters which is capable of providing accurate measurements and test results. The electronic components used in the manufacturing of the offered Digital Clamp-On-Multimeter With VFD Function are of top grade to assure long life.

DIGITAL CLAMP-ON-MULTIMETER WITH VFD FUNCTION KM 181

Special Features

  • VFD-V & VFD-Hz function
  • 5ms CREST-MAX capture mode (Peak Hold)
  • Autoranging Relative -Zero mode
  • Data Hold function
  • EF-Detection (NCV)
  • PC Interface (Optional)
  • AutoCheck TM Voltage & Ohms
  • Hz Line Level Frequency
  • Manual / Autoranging range selection.
  • Auto Power Off
  • Diode Test & Continuity Test

General Specifications

  • Sensing : Average sensing
  • Jaws Opening size : 26 mm Max.
  • Display : 3-5/6 digits 6000 counts & 3½ digits 1,999 counts for Hz.
  • AC Current (Clamp on) (50Hz – 400Hz) : 60A ~ 600A
  • AC  Voltage (50Hz ~ 400Hz) : 6V ~ 600V
  • DC  Voltage :  6V ~ 600V
  • AUTOCHECK TM DCV : 6V ~ 600V
  • AUTOCHECK TM ACV (with Low Pass Filter) (5Hz – 420Hz): 6V ~ 600V
  • AUTOCHECK TM OHM : 600 Ohm ~ 60 Mega Ohm
  • Capacitance : 60nF ~ 2000 µF
  • Hz Line Level Frequency : 10Hz ~ 1999Hz
  • Update Rate : 5 per second nominal
  • Polarity : Automatic
  • Low Battery : Below approx 2.4V
  • Operating Temperature : 0°C to 40°C
  • Relative Humidity : Maximum 80% R. H. For temperature upto 31°C decreasing linearly to 50% Relative Humidity at 40°C
  • Altitude : Operating below 2000m
  • Storage Temperature : -20°C to 60°C, < 80% R.H. (With battery removed)
  • Temperature Coefficient : nominal 0.15 x (specified accuracy) / °C @ (0°C--18°C or 28°C--40°C), or otherwise specified
  • Power supply : Standard 1.5V AAA Battery x 2.
  • Power Consumption : 5.2mA typical
  • APO Timing : Idle for 34 minutes
  • APO Consumption : 10µA typical
  • Dimension : 190(L) x 63(W) x 32(H) mm
  • Weight : Approx. 179gm.

Safety

  • Double insulation per IEC61010-1 2nd Ed., EN61010-1 2 nd Ed., UL61010-1 2 nd Ed., & CAN/CSA C22.2 No.61010.1-0.92 to Category III 600V & CAT IV 300V AC & DC.
  • Transient Protection: 6 kV (1.2/50µs surge)
  • EMC: Meets EN61326-1:2006 (EN55022, EN61000-3-2, EN61000-3-3, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11)
  • In an RF field of 3V/m : Capacitance function is not specified
  • Other function ranges : Total Accuracy = Specified Accuracy + 100 dgts
  • Performance above 3V/m is not specified.
  • Overload Protection
    • ACA Clamp-on jaws : AC 600A rms continuous "+" & COM Terminals (all other functions) : 660V DC / V AC rms

DC Voltage

Range

Resolution

Accuracy

6.000 V

1 mV

±(0.5%rdg + 5dgts)

60.00 V

10 mV

600.0 V

100 mV

600 V

1 V

Added range to indicate instantaneous over-range voltage values.

Input Impedance : 10MW, 50pF nominal

AC Voltage

Range

Resolution

Accuracy

50 Hz ~400Hz



6.000 V

1 mV

±(1.2% rdg + 5 dgts)

60.00 V

10 mV

600.0 V

100 mV

600 V

1 V

Added range to indicate instantaneous over-range voltage values.

Input Impedance : 10MW, 50pF nominal

AUTO CHECKTM OHM

Range

Resolution

Accuracy

600.0

0.1

±(0.5%ordg + 5 dgts)

6.000 KΩ

1

60.00 KΩ

10

600. 0 KΩ

100

±(0.8%ordg + 5 dgts)

6.000 MΩ

1 KΩ

±(1.2%ordg + 5 dgts)

60.00 MΩ

10 KΩ

±(2.2%ordg + 5 dgts)

Open Circuit Voltage : 0.45VDC typical.

Auto Check Ohm Threshold : <10.00MΩ nominal.

Auto check ACV (with low pass Filter )

Range

Resolution

Accuracy

5Hz ~ 20Hz



6.000 V

1 mV

±(3.0%ordg + 80dgts)

60.00 V

10 mV

600.0 V

100 mV

600 V2

1 V

20Hz ~ 200Hz



6.000 V

1 mV

±(2.0%ordg + 50dgts)

60.00 V

10 mV

600.0 V

100 mV

600 V2

1 V

200Hz~420Hz3



6.000 V

1 mV

±(6%ordg + 80dgts)

60.00 V

10 mV

600.0 V

100 mV

600 V2

1 V

  • Not specified for fundamental frequency > 420Hz
  • Added range to indicate instantaneous over-range voltage values
  • Accuracy linearly decreases from 2% + 50d @ 200Hz to

6% + 80d @ 420Hz

Auto Check Lo-Z ACV Threshold : >1V (50/60Hz) nominal.

Auto Check Lo-Z ACV input impedance :

Initially approx. 2.5kW, 200pF nominal; impedance increases

abruptly within a fraction of a second as display voltage is

above 50V (typical). Ended up impedance vs display

voltages typically are :

15 kΩ @ 100V

100kΩ @ 300V

250kΩ @ 600V


KUSAM ELECTRICAL INSTRUMENTS LLP

Contact Us

( *represents compulsory fields )

Tips on getting accurate quotes. Please include product name, order quantity, usage, special requests if any in your inquiry.



KUSAM ELECTRICAL INSTRUMENTS LLP
G-17, Bharat Industrial Estate, T-J Road, Sewri-West,Mumbai - 400015, Maharashtra, India
Mr. Pradeep (Director)

Product Showcase
   Call Me Free Offline Send SMS Send Inquiry